CGFSB - EPOXY, 187
- MSDS: CGFSB
- Manufacturer: PLASTI KOTE CO INC
- Product Name: EPOXY, 187
- National Stock Number: 8010-00N027326
Product Identification
Product ID:EPOXY, 187
MSDS Date:09/16/1994
FSC:8010
NIIN:00N027326
MSDS Number: CGFSB
Responsible Party
MEDINA, OH 44256
US
Emergency Phone: 800-255-3924
Info Phone: 330-725-4511
Preparer: RAY MALLANEE
Cage: 07778
Contractor
Telephone: 330-725-4511
Cage: 07708
Ingredients
186 @ 20C
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: 25-30%
OSHA PEL 1000 PPM
ACGIH TLV: 750 PPM; 1000 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
5.1 @ 20C
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 25-30%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM; 150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
HYDROCARBON PROPELLANT (PROPANE/ISOBUTANE)
CAS: 68476-86-8
Fraction By Weight: 27%
OSHA PEL N/K
ACGIH TLV: N/K
WEAR NIOSH APPROVED RESPIRATORY PROTECTION
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: EXCESSIVE INHAL OF
VAPORS CAN CAUSE NASAL & RESPIRATORY IRRITATION, DIZZINESS,
WEAKNESS, FATIGUE, NAUSEA, HEADACHE, POSSIBLE UNCON & EVEN
ASPHYXIATION. EYE CONTACT: CAN CAUSE SEVERE IRRI TATION, REDNESS,
TEARING, BLURRED VISION. INGEST: CAN CAUSE GI IRRITATION, NAUSEA,
VOMITING, DIARRHEA. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: SKIN CONTACT: CAN CAUSE IRRITATION
FOR SOME PERSONS. CHRONIC: REPORTS HAVE ASSOCIATED RPTD & PRLNGD
OCCUPATIONAL OVEREXP TO SOLVENTS W/PERMANENT BRAIN & NERVOUS SYSTEM
DAMAGE. SEVERE OVEREXP IN LAB ANIMALS HAS ALSO CAUSED LIVER
ABNORMALITIES & DAMAGE TO KIDNEYS, LUNGS & SPLEEN, HEART &
ADRENALS. (SUPDAT)
Medical Cond Aggravated by Exposure:CAN CAUSE RESPIRATORY AND/OR SKIN
REACTION.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. IF BREATHING IS DFCLT, ADMINISTER
OXYGEN. IF BREATHING HAS STOPPED, GIVE ARTF RESP & SEEK MED HELP.
EYES: FLUSH W/WATER FOR AT LEAST 15 MIN WHILE HOLDING EYELIDS OPEN.
INGE ST: DO NOT INDUCE VOMIT (ASPIR OF MATL INTO LUNGS CAN CAUSE
PNEUMONIA; CAN BE FATAL). KEEP WARM, QUIET & GET MED ATTN/POIS CTL
CTR. SKIN: WASH W/SOAP & WATER OR VARIOUS HAND CLEANERS. WASH
CLOTHING.
Fire Fighting
Flash Point Method:TCC
Flash Point:0F,-18C
Lower Limits:1.0%
Extinguishing Media:ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFTIVE. WATER MAY BE USED TO COOL CLOSED
CNTNRS TO PREVENT PRESSURE BUILDUP & POSS (SUPDAT)
Unusual Fire/Explosion Hazard:CLOSED CNTNRS MAY EXPLODE &/OR AUTOIGNITE
WHEN EXPOSED TO EXTREME HEAT. VAPORS ARE HVR/AIR & MAY TRAVEL ALONG
GROUND OR MAY BE MOVED BY VENT & IGNITED (SUPDAT)
Accidental Release
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. VENTILATE
AREA. ABSORB LIQUID ON PAPER, VERMICULITE, FLOOR ABSORBENT OR OTHER
ABSORBENT MATERIAL AND TRANSFER TO A CLOSED CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT PUNCTURE OR INCINERATE. DO NOT
STORE IN AREAS ABOVE 120F OR IN DIRECT SUNLIGHT OR NEAR HEAT OR
OPEN FLAMES.
Other Precautions:STORE LARGE QUANTITIES IN BUILDING PROTECTED FOR
STORAGE OF FLAMMABLE LIQUIDS.
Exposure Controls
Respiratory Protection:FOR CASUAL/OCCASIONAL USE-TO AVOID BREATHING
VAPORS OR SPRAY MIST, OPEN WINDOWS & DOORS OR USE OTHER MEANS TO
ENSURE FRESH AIR ENTRY DURING APPLICATION & DRYING. IF YOU
EXPERIENCE EYE WATERING, HDCH O R DIZZ, INCREASE FRESH AIR, (ING 4)
Ventilation:FOR REGULAR/CONTINUOUS USE-PROVIDE SUFFICIENT MECH (GEN)
&/OR LOC EXHST VENT TO MAINTAIN EXPOS BELOW LISTED TLVS.
Protective Gloves:CHEM RESIST GLOVES SUCH AS NEOPRENE.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . WHERE
SPEC/UNUSUAL CNDTNS EXIST, SEEK EXPERT ASSISTANCE OF INDUS
HYGIENIST.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING WASHROOM. AS
WITH ALL CHEMICALS, MINIMIZE PERSONAL CONTACT.
Supplemental Safety and Health
FIRE FIGHT PROC: AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. IF WATER
IS USED, FOG NOZZS ARE PREF. EXPLO HAZ: BY PILOT LIGHTS, OTHER
FLAMES, SPKS, HEATERS, SMOKING, ELEC MOTORS OR OTHER LOCATIONS DI
STANT FROM MATL HNDLG POINT. EFTS OF OVEREXP: INTENTIONAL MISUSE BY
DELIB CONC & INHAL CONTENTS MAY BE HARMFUL/FATAL.
Chemical Properties
Boiling Pt:B.P. Text:>133F,>56C
Melt/Freeze Pt:M.P/F.P Text:1500F,816C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:<1 (H*2O=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:SLIGHT TO MODERATE
Appearance and Odor:TYPICAL SOLVENT PAINT.
Percent Volatiles by Volume:80-90
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS AND HEAT.
Stability Condition to Avoid:HEAT, SPARKS AND OPEN FLAME.
Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS, CARBON
DIOXIDE/CARBON MONOXIDE, VARIOUS HYDROCARBONS, NITROGEN COMPOUNDS,
ETC, WHEN BURNED.
Disposal
Waste Disposal Methods:MATERIAL COLLECTED ON ABSORBENT MATERIAL MAY BE
DEPOSITED IN A POSTED TOXIC SUBSTANCE LANDFILL IN ACCORDANCE WITH
LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.